Selecting output terminal type

Introduction

This table defines the type of output terminal that the applications will choose automatically, according to the following parameters:

  • Type of conductor
  • Rating current
  • Rating voltage

Table fields (Selecting output terminal type)

  • Conductor type: enter the conductor type according to the following code:
    1 = Flat wire
    2 = Foil
    3 = Wire
    4 = Multi wire
    In case the output type is valid for more than one conductor, enter 1 code in sequence.
    Esempio: Example: If the output type is valid for both wire and flat wire enter: 13 .
  • Max current A: maximum rated current for which that type of output can be used.
  • Max voltage V: maximum rated voltage for which that type of output can be used.
  • Selecting output terminal type: output terminal type code:
    1 = Terminal blocks in lists
    2 = minal blocks on rail
    3 = Lugs
    4 = External bars (used when the winding is in flat wire, but the current does not allow for the use of lugs). They are bars fixed to a plate or an insulator to which the flat wire, coming off the coil, is welded.
    5 = Bars inside the foil winding.
  • Description: the description of the type of output is inserted in the table for clarity.