Printed lamination - bobbin /

This standardisation requires aluminium windings and NO grain not oriented laminations. For different conditions, the proportioning is not optimised.

Table Fields (Printed lamination - bobbin)

  • Std.: element type coding, which must be strictly adhered to. If a new type of element is to be added, you must contact us for the choice of code. Here are the meanings of the letters used:
    IDC = single-phase DC inductors
    IAC = single-phase AC inductors
    TR = three-phase and single-phase Transformers
  • Phases nr.: 1 = single-phase 3 = three-phase.
  • Power VA: dimensioning power of the element in VA.
  • Printed lam. code: Printed lamination type (ex: EIT , EI , UI)
  • Printed lam. length: Printed lamination Length.
  • Flux density T: recommended flux density (for NO core) .
  • Core section cm2: section of the core (column) which is calculated as follows: Core width x Core thickness x 0.97.
    0.97 gives the actual cross-section, after deducting the spaces occupied by the insulation of the individual laminations.
  • Core Width: the width of the core sheet of the column (The core thickness is calculated automatically by the application, starting from the core section, taking into account the formula above).
  • Core thickness: The core thickness is calculated from the raw core section. Must be consistent with core section and core width.
  • Window width: The window width is the space between the columns. In this case, once the of the printed lamination has been chosen, it is a fixed value.
  • Window height: window height is defined as the space between the two yokes. In this case, once the of the printed lamination has been chosen, it is a fixed value.
  • Front. core/coil ch.: thickness of the frontal space between core and coil. The thickness of the bobbin plus any frontal channel can be inserted.
  • Side core/coil ch.: thickness of the side space between core and coil. The thickness of the bobbin can be inserted. It is not possible to insert a side ventilation channel for this kind of element.
  • Bobbin type: Bobbin identification according to suppliers' rules.
  • Winding height: Net height available for windings (all windings are set to the same height).
  • Channel between wdgs: thickness of the front channel between the windings. This channel is used between the primary and secondary.
  • Partwdg int. windings: No. of partwindings of the internal winding.
  • Channel int. windings.: thickness of the frontal channel between partwindings. This channel is used in the internal winding.
  • Partwdg ext. winding: No. of partwindings of the external winding.
  • Channel ext. winding: thickness of the frontal channel between partwindings. This channel is used in the external winding.
  • Description: free descriptions of the type of element being designed are not included in the applications, so you can write descriptions as you see fit.