Interlayer insulation thick

Introduction

This table is used only in Clever Small-T and Clever Small-I applications to choose automatically the thickness of the insulation between layers and between windings. The thicknesses automatically chosen by the applications, within a design, can be changed manually.

Table fields (Interlayer insulation)

  • Temperature class: Element temperature class (A-E-B-F-H).
  • Conductor material: Conductor material code.
    0 = Aluminum
    1 = Copper
  • Conductor type: Enter the conductor type according to the following code:
    1 = Flat wire
    2 = Foil
    3 = Wire
    4 = Multi-wire
  • Nr. of // radial conductors: Number of conductors in radial parallel. With the same thickness, the thickness of the insulation generally has to be increased if there are more conductors in // radial.
  • Conductor thickness: The thickness of the single conductor.
  • Insulation thickness: Suitable insulation thickness. No distinctions are made among the various insulating materials because the problem is mainly mechanical.
  • Index: Value needed by the software. If you need to add a line, proceed as follows:
    • Sort the table by index to find out the latest number
    • Enter the next number as per the index.